Micro Direct
PulmoLife COPD Screening Device
Click here for BBB Business Review
click to enlarge
PulmoLife COPD Screening Device
PulmoLife is a new COPD screening device, designed for quick and easy screening of adult smokers for early detection of COPD. Smokers are at the greatest risk of developing COPD and decline in lung function in susceptible smokers has been shown to be twice that of non-smokers.


This small, innovative device measures FEV1, the measurement of choice in COPD screening. The unit will display a patient’s result together with the FEV1 as a percentage of their predicted value. These results are used to calculate a ‘Lung Age’. The associated ‘Lung Age’ graphical display may help the patient realise the physical damage caused by smoking, encouraging attendance for smoking cessation advice and full spirometry assessment, leading to early diagnosis and appropriate management of COPD.

product literature

PL10 PulmoLife $195
Suitable for:
  • FEV1 testing programs
  • Identification of early signs of COPD in smokers over 40 or anyone with symptoms
  • Helping susceptible smokers to quit

FEV1 and FEV1 % predicted
Forced Expiratory Volume in the First Second of Expiration. The use of FEV1 is well documented as a  useful diagnostic tool for the detection of early COPD. When comparing its result against predicted values  and using patients FEV1 result as a percentage of predicted values (FEV1 % predicted) the likelihood and  severity of COPD can be seen.

‘Lung Age’
In addition to comparing patients FEV1 results with the predicted reference values for normal subjects,  estimation of ‘Lung Age’ can be used to demonstrate to smokers the damage caused to their lungs by  smoking in a way they can understand. The ‘Lung Age’ estimation is based on a patients FEV1 results and  predicted values. A ‘Lung Age’ example; a 40 year old 5’9” (1.75m) male smoker has an FEV1 of 3.4L  giving an estimated ‘Lung Age’ of 52 years. This is because the FEV1 is 100% of the predicted value that a 52 year old would be expected to get.

Features
  • Measures FEV1 – the measurement of choice in COPD screening
  • Gives FEV1 result as a percentage of predicted values
  • ‘Lung Age’ Interpretation (Morris and Temple)
  • Used as a motivational tool for smoking cessation

PulmoLife continues the Micro Direct tradition of being accurate and simple to use and provides health professionals with a useful and unique mass-screening tool to help reduce the burden of chronic lung disease.

Specification
Transducer: Micro Direct Gold Standard Bi-Directional Digital Volume
Resolution: 10ml
Accuracy: +/-3% (meets and exceeds all known spirometry performance standards)
Volume range: 0 - 8 Liters
Flow range: 0 - 14 Liters/Second
Predicted values: 1) ECCS
2) NHANES III
3) Asian (Chinese)
Display: Custom Liquid Crystal
Power Supply: 3V Lithium Ion Coin Cell Battery
Dimensions: 5.1" x 2.3" x 1.5"
Weight: 3.4 oz
Operating temperature: 32 to 104 °F
Operating humidity: 30% to 90% RH
Storage temperature: 32 to 158 °F
Storage humidity: 10% to 90% RH